Discover the power and versatility of 1/0 SER cable in our comprehensive shopping guide. Ideal for heavy-duty electrical projects, this robust cable ensures safe and efficient transmission of energy in residential, commercial, and industrial settings. Whether you’re upgrading your panel or planning a new installation, learn how 1/0 SER cable can meet your electrical needs with reliability and flexibility.

Comparing Types and Applications of 1/0 SER Cable

Variation/Type Material No. of Conductors Ground Included Common Use Case Voltage Rating Notable Attributes
1/0-1/0-1/0-2 Aluminum SER Aluminum 3 (Phase & Neutral) + 1 Ground Yes Service entrance, panel feeds 600V Cost-effective, lightweight
1/0-1/0-1/0-2 Copper SER Copper 3 (Phase & Neutral) + 1 Ground Yes Service entrance, panel feeds 600V Higher conductivity, flexible
1/0-1/0-1/0 AL URD (Underground) Aluminum 3 No (bare ground, if present) Direct bury, outdoor feeders 600V Rated for underground use
1/0-1/0-1/0-2 SEU (Aluminum/Copper) Aluminum/Copper 2 (Phase & Neutral) + Ground Yes Subpanel feeds, reduced space 600V Concentric neutral, compact

Types of 1/0 SER Cable

Overview of 1/0 SER Cable Types

1. Aluminum SER Cable

  • Composed of aluminum alloy conductors.
  • Lightweight and cost-effective.
  • Most common for residential feeders and service entrances.
  • Features a durable PVC outer jacket and XHHW or THHN/THWN insulation.

2. Copper SER Cable

  • Contains copper conductors for enhanced conductivity and flexibility.
  • Offers better resistance to corrosion, ideal for demanding environments.
  • More expensive but preferred for longer runs or higher durability requirements.

3. URD (Underground Residential Distribution) Cable

  • Designed for direct burial without conduit.
  • Often does not include an insulated ground; sometimes includes a bare concentric ground.
  • Used for utility-to-building underground feeds.

4. SEU vs. SER

  • SER (Service Entrance, Round): Multiple phase and neutral conductors with an insulated or bare ground; suitable for various feeder and main service applications.
  • SEU (Service Entrance, Unarmored): Typically two insulated conductors and a smaller concentric neutral, plus bare ground; more compact, used for main service panels or subpanels where space is a concern.

Typical Uses of 1/0 SER Cable in Home or Office

Residential Applications

  • Main Service Panel Feeds: Connecting the main service disconnect to an indoor panel.
  • Subpanel Feeder: Running from the main panel to a subpanel in a detached garage, workshop, or addition.
  • Meter Base to Distribution Panel: Providing a reliable path for electrical supply from the meter to interior distribution.

Office & Light Commercial Uses

  • Feeding Sub-distribution Panels: Supplying power in small office suites, outbuildings, or light commercial facilities.
  • Retrofits and Upgrades: Used in updating old wiring to enhance capacity and code compliance.
  • Above-ground Feeder Lines: When permitted by code, supplies rooftop HVAC units or lighting.

Key Points:

  • Rated for 600 volts and useable in wet or dry locations above ground.
  • Not intended for direct burial unless specified as “URD” or a direct-burial variant.
  • Commonly cut to length for custom installations.

Safety Considerations for 1/0 SER Cable

  1. Correct Sizing: Always verify the ampacity and voltage requirements for your application to avoid overload and overheating.
  2. Termination: Use only compatible connectors and lugs, rated for aluminum or copper (as appropriate).
  3. Installation Method: SER cable must be protected from physical damage. Use conduit or mechanical protection where required by code.
  4. Ambient Temperature De-rating: Ampacity can decrease in high ambient temperatures or certain installation conditions. Refer to NEC tables for adjustments.
  5. Proper Support: Cables should be securely fastened every 4.5 feet and within 12 inches of junction boxes/panels.
  6. Compatible Panels: When connecting to a distribution panel, ensure the panel accepts the cable size and material.
  7. Code Compliance: Always follow local and National Electrical Code (NEC) requirements for routing, securing, and terminating cables.
  8. Professional Installation: Improper installation can lead to safety hazards, so consider hiring a licensed electrician for critical connections.

How to Choose the Right 1/0 SER Cable for Your Project

1. Determine Ampacity Requirements

  • Calculate the maximum load your circuit will carry.
  • 1/0 SER aluminum typically rated for 135A at 75°C (per NEC), but actual rating depends on installation.

2. Choose Material: Copper vs. Aluminum

  • Aluminum: Lower cost, lighter, but requires proper anti-oxidant compound at connections.
  • Copper: Higher upfront cost, more flexible, better conductor for long runs and harsh environments.

3. Select the Correct Type (SER vs SEU vs URD)

  • SER: Use for above-ground feeder/service entrance, offers more circuits and flexibility.
  • SEU: More compact, fewer conductors—use where space-saving is crucial.
  • URD: For direct-burial/outdoor applications.

4. Verify Compatibility with Panels and Devices

  • Ensure lugs, breakers, and panels accept the conductor size and material.

5. Check Jacket and Insulation Ratings

  • PVC jacketing: For indoor or above-ground use.
  • Sunlight-resistant: Needed for outdoor runs exposed to sunlight.

6. Length and Customization

  • Buy by the foot or reel. Order slightly more than measurement to account for routing or mistakes.

Practical Tips and Best Practices

  • Plan Your Run: Carefully map your cable route to minimize length and avoid unnecessary bends.
  • Use Anti-Oxidant Paste: Always apply anti-oxidant compound to aluminum connections to prevent corrosion and ensure lasting performance.
  • Measure Twice, Cut Once: Since SER is often sold by the foot, accurate measurement can save money and avoid waste.
  • Label Cables: When running multiple cables, label both ends to simplify future maintenance.
  • Leave Service Slack: Include a small “service loop” at panels in case future re-termination is necessary.
  • Read Local Codes: Building codes may have additional requirements beyond the NEC.
  • Professional Help: For main service or major upgrades, hiring a licensed electrician is strongly advised for correctness and safety.

Technical Specifications Comparison Table

Attribute 1/0 AL SER Cable 1/0 CU SER Cable 1/0 AL URD Cable
Material Aluminum Copper Aluminum
No. of Conductors (w/ ground) 3 + 1 Ground 3 + 1 Ground Usually 3
Insulation Type XHHW-2/THHN/THWN-2 XHHW-2/THHN/THWN-2 XHHW-2
Outer Jacket Sunlight-Resistant PVC Sunlight-Resistant PVC Direct-burial rated PE or PVC
AWG Conductor Size 1/0 1/0 1/0
Ampacity @ 75°C ~135A (NEC Table) ~150A (NEC Table) ~135A
Voltage Rating 600V 600V 600V
Typical Application Above-ground feeder, main service Above-ground, main service Direct-burial main/sub-feed
Weight (per 1,000 ft) ~540 lbs Higher (varies, ~800+ lbs) ~540 lbs
Flexibility Moderate Higher Moderate
Cost $$ $$$$ $$
Code Compliance NEC, UL, ASTM NEC, UL, ASTM NEC, UL, ASTM
Termination Al/Cu Lugs Cu Lugs Al/Cu Lugs

Related Video

Conclusion

Choosing the right 1/0 SER cable is critical for any major electrical project, whether upgrading a residential service or installing a new subpanel for an office. Carefully consider the electrical load, cable material, environment, and installation method. Always prioritize safety and code compliance, and don’t hesitate to consult a licensed electrician when in doubt. With the correct 1/0 SER cable, you ensure both performance and peace of mind for years to come.


FAQ

What does “SER” stand for in 1/0 SER cable?
SER stands for “Service Entrance, Round.” It refers to a type of cable used for service entrance and feeder applications, built with multiple conductors (phases and neutral) plus a separate ground, encased in a round PVC jacket.

Can I use 1/0 SER cable outdoors?
Yes, 1/0 SER cable can be used outdoors if it is above ground and protected from direct exposure to damage. The jacketing is sunlight-resistant. However, it is not rated for direct burial—use an underground rated cable like URD for that purpose.

What is the ampacity of 1/0 SER cable?
The ampacity (current-carrying capacity) of 1/0 aluminum SER cable is typically around 135 amps at 75°C per NEC tables, while copper is around 150 amps. Always consult the latest NEC and local codes.

Should I choose copper or aluminum 1/0 SER cable?
Copper offers better conductivity and flexibility, ideal for longer runs or harsher environments, but is more expensive. Aluminum is lighter and more affordable, commonly used in standard residential and light commercial settings.

Can 1/0 SER cable be used for subpanels?
Yes, 1/0 SER cable is commonly used as a feeder from the main panel to subpanels located in garages, additions, or secondary buildings, so long as ampacity and code requirements are met.

What is the difference between SER and SEU cable?
SER cable has multiple phase conductors plus a neutral and ground, making it more versatile for panels requiring multiple circuits. SEU is typically used for simpler applications with two conductors and a concentric neutral, resulting in a slimmer profile.

Why do aluminum cables require anti-oxidant paste at connections?
Aluminum can oxidize, leading to increased resistance and possible overheating at terminations. Anti-oxidant paste helps prevent corrosion and ensures a safe, long-lasting connection.

How often must SER cable be supported or secured?
Per code, SER cable must be secured every 4.5 feet and within 12 inches of each junction box or panel board to prevent sagging or damage.

What’s the maximum length I can run 1/0 SER cable without voltage drop issues?
It depends on load and cable material. For typical residential loads (100-135A) over 100 feet, you may need to consider going up a size or using copper instead of aluminum to prevent excessive voltage drop. Calculate specifically for your application.

Can I install 1/0 SER cable myself or do I need a licensed electrician?
You may be able to handle simple feeder installations if you have experience and your local codes allow it, but for main service entrance or major projects, a licensed electrician is strongly recommended for safety and compliance.