Protecting your home’s water supply is essential, and a dual check valve backflow preventer is a smart solution. This simple yet effective device safeguards against water contamination by ensuring water flows in only one direction. If you’re a homeowner or DIY enthusiast looking to enhance safety and compliance, our shopping guide will help you choose the best dual check valve backflow preventer for your needs.

Comparison Table: Types and Applications of Dual Check Valve Backflow Preventers

Type/Variation Typical Applications Functionality Example Installations Level of Protection
Standard Dual Check Valve Residential water lines, small outlets Prevents reverse water flow Water meter inlet, supply lines Non-health hazard
Dual Check Valve with Atmospheric Vent Beverage machines, small appliances Prevents backflow & provides venting Coffee machines, vending machines Increased non-hazard
Double Check Valve Assembly Fire sprinkler systems, pools, irrigation Two check valves in series for added safety Lawn sprinklers, fire protection Non-health hazard
Dual Check for Small Supply Lines Laboratory, processing tanks, small boilers Compact design for tight spaces Lab sinks, small medical equipment Non-health hazard
Lead-Free Dual Check Valve Potable drinking water systems Constructed without lead for safe water Main water supply, filtration units Non-health hazard

Understanding Dual Check Valve Backflow Preventers

Dual check valve backflow preventers are critical plumbing devices designed to safeguard drinking water supplies from contamination or pollution caused by backflow. In essence, these valves only allow water to flow in one direction, preventing the reversal of potentially contaminated water into clean water lines.

Types of Dual Check Valve Backflow Preventers

1. Standard Dual Check Valve

  • Contains two back-to-back check valves within a single housing.
  • Typically used in residential plumbing at the main water entry point.
  • Provides basic protection against non-health (low) hazard pollutants–for example, from garden hoses or irrigation systems.

2. Dual Check Valve with Atmospheric Vent

  • Includes an atmospheric vent to provide extra protection.
  • Often installed in machines like vending or beverage units, where even minor cross-connection risks exist.
  • The vent allows any minor leakage to escape to the atmosphere, reducing the risk of backflow contamination.

3. Double Check Valve Assembly

  • Features two independently operating check valves in the same assembly.
  • Used in both residential and light commercial settings, especially where frequent backpressure or backsiphonage is expected (e.g., fire sprinkler systems, pools).
  • Provides greater safety against the unwanted reverse flow of water.

4. Specialty Dual Check Valves for Small or Sensitive Applications

  • Compact versions designed for installation in tight spaces.
  • Used for specific equipment such as laboratory gear, processing tanks, boilers, and sterilizers.

5. Lead-Free Dual Check Valves


Double Check Valve Assemblies - Watts - dual check valve backflow preventer

  • Constructed using lead-free alloys and plastic parts.
  • Recommended (and often required by code) for any system supplying potable water to avoid lead contamination.

Functions and Importance

What Do Dual Check Valve Backflow Preventers Do?

  • Prevent Backflow: They stop contaminated or used water from re-entering the clean water supply, protecting health and water quality.
  • Support Water Pressure Integrity: By preventing reversal of flow, these devices also help maintain system pressure consistency.
  • Comply with Plumbing Codes: Many building codes require backflow preventers to be installed depending on the specific cross-connection risk.

Typical Functions:

  • Check Valves: Respond to pressure changes; when water tries to flow backward, the check valves close automatically.
  • Atmospheric Vent (on specific models): Provides visual or detectable signs of valve failure and additional air gap protection.

How to Choose the Right Dual Check Valve Backflow Preventer

Selecting the ideal dual check valve backflow preventer depends on your specific water system, risk level, and local regulations.

For Home Plumbing or Small Setups:

1. Identify Application and Risk Level

  • For main water entry points in homes, a standard lead-free dual check valve is suitable for low-hazard conditions.
  • For appliances with a higher backflow risk (like beverage or coffee machines), choose a model with an atmospheric vent.
  • For fire sprinklers, pools, or irrigation, opt for double check valve assemblies rated for continuous pressure and larger pipe sizes.

2. Check Compatibility

  • Pipe Size: Ensure the valve matches your pipe diameter.
  • Pressure Ratings: Choose a valve suitable for your system’s minimum and maximum working pressures (commonly 10–150 psi for home use).
  • Installation Orientation: Some dual check valves can be installed vertically or horizontally; confirm this based on available space.

3. Materials and Safety

  • Lead-Free Construction: Only use lead-free backflow preventers for drinking water systems.
  • Durability: Look for valves with corrosion-resistant bodies (often bronze, copper alloy, or stainless steel) and replaceable internal check valves for easier maintenance.

4. Certifications and Local Codes

  • Always check with your local plumbing inspector or authority to confirm which types and certifications are required for your application.

Practical Tips and Best Practices

  • Installation Location: Install immediately downstream of the water meter for main supply protection, or right at the point of use (for appliances).
  • Regular Inspection: Though maintenance requirements are low, periodic visual inspection for leaks or damage ensures reliability.
  • Obey Flow Direction: Always install so the arrow on the body matches the intended water flow.
  • Avoid Exposure: Protect valves from freezing, excess heat, and direct sunlight to extend their lifespan.
  • Test Annually: While dual check valves aren’t field-testable like some assemblies, have your water system periodically checked, especially if water quality issues are suspected.
  • Replace if Faulty: If a valve shows signs of reverse leakage or malfunctions, replace it promptly to maintain health protection.
  • Labeling: Clearly label any backflow preventers in your system for future reference or servicing.

Technical Comparison Table: Dual Check Valve Backflow Preventer Attributes

Attribute/Model LF7 (Watts) LF7R (Watts) Standard Dual Check Dual w/ Atmospheric Vent Double Check Valve Assembly
Body Material Lead-free Bronze Lead-free Bronze Varies (Bronze/Copper) Brass or Polymer Bronze/Iron
Internal Check Materials Replaceable Plastic Replaceable Plastic Plastic/Brass Plastic/Brass Plastic/Stainless
Springs Stainless Steel Stainless Steel Stainless/Phosphor Bronze Stainless Steel Stainless Steel
Minimum/Maximum Pressure 10–150 psi 10–150 psi 10–150 psi 10–150 psi 10–175 psi
Installation Orientation Vertical/Horizontal Vertical/Horizontal Varies Varies Vertical/Horizontal
Pipe Sizes Available 1/2″ – 2″ 1/2″ – 2″ 1/2″ – 2″ 1/4″ – 1″ 3/4″ – 2″
Suitable for Potable Water Yes Yes Yes No (Unless specified) Yes
Applications Residential Non-health hazard Home/Small Outlets Appliances, Vending Fire, Irrigation, Pools
Atmospheric Vent No Yes (LF7R) No Yes No
Field Testable No No No No Yes (Some models)
Typical Approvals ASSE, CSA ASSE, CSA ASSE, CSA ASSE, CSA ASSE, CSA
Typical Maintenance Check Inserts Check Inserts Replace if failed Replace if failed Replaceable checks

Note: Specifications and features vary by manufacturer; always check the specific datasheet for technical details.


Related Video

Conclusion

Choosing the right dual check valve backflow preventer is essential for protecting your home or small business’s water supply from contamination. Understand your unique system needs, identify the risk level of potential cross-connections, and always verify with local codes before purchasing.

Opt for a lead-free, appropriately sized, and reputable product that matches your plumbing configuration. Regular inspection and prompt replacement of any failed units are your best defenses against unwanted backflow. By following this guide, you can ensure both peace of mind and continued water safety for your family or facility.


FAQ

  1. What is a dual check valve backflow preventer?
    A dual check valve backflow preventer is a plumbing device with two internal check valves arranged in series. Its purpose is to prevent used or contaminated water from reversing flow and entering the clean water supply.

  2. Where should I install a dual check valve backflow preventer in my home?
    Most commonly, install it immediately downstream of the residential water meter or at the supply inlet for sensitive appliances, as required by local code.

  3. What’s the difference between a dual check and a double check valve assembly?
    While both use two check valves, double check assemblies often have test ports and are designed for more demanding applications. Dual check valves are usually non-testable and suited to lower hazard applications.

  4. Do I need a lead-free valve for drinking water?
    Yes. For potable (drinking) water, codes typically require certified lead-free valves to avoid the risk of lead entering the water supply.

  5. How often should I replace or inspect a dual check valve backflow preventer?
    Visual inspections should be performed annually, and immediate replacement is recommended if you notice leaks or signs of failure.

  6. Can dual check valves be used for health hazard (high-risk) applications?
    No. Dual check valves are generally approved for non-health hazard situations only. High hazard (health-critical) applications require specialized and more robust preventers (such as reduced pressure assemblies).

  7. Can I install a dual check valve vertically and horizontally?
    Yes, many models (like the Watts LF7) are designed for both vertical and horizontal installation, but always verify the manufacturer’s instructions.

  8. What pipe sizes do dual check valves come in?
    Typical residential and small commercial models come in sizes from 1/2″ up to 2″, but check available sizes for your brand and application.

  9. Do dual check valves require maintenance?
    They require little maintenance, but periodic inspection to check for proper operation, leaks, or signs of wear is important. Some have replaceable check inserts.

  10. How do I know if my local code requires a dual check backflow preventer?
    Check with your local water supplier or plumbing authority—they set requirements based on the potential cross-connection risks and may specify the exact type, model, or certifications needed.